HAST (Highly Accelerated Temperature and Humidity Stress Test)

Procedure: JESD22-A110-B / JESD22-A118

Purpose: The highly accelerated temperature and humidity stress test is performed for the purpose of evaluating the reliability of non-hermetic packaged solid-state device in an environment with high humidity. It employs severe condition of temperature, humidity, and bias, which accelerate the penetration of moisture through the external protective material (encapsulated or seal) or along the interface between the external protective material and the metallic conductor, which pass through it. Samples of surface mount devices are subjected to preconditioning and a final electrical test prior to the highly accelerated temperature and humidity stress test.

Thermal Shock (Liquid to Liquid)
Procedure: MIL-STD-883 Method 1011.9 / JESD22-A106-A

Purpose: Thermal shock testing is similar to temperature cycle testing, except that in thermal shock tests an additional stress is provided: a sudden change in temperature due to a rapid transfer time. Thus the test can detect failure mechanisms caused by temperature transients and temperature gradients. The cycling test system has one fluorocarbon bath at -65 or –55 °C (LCD driver) and the other fluorocarbon bath at 150 or 125 °C. During thermal shock testing, devices are inserted into the cycling test system and held at cold dwell for 5 minutes and then heated to hot dwell for 5 minutes. One cycle includes the duration at both extreme temperatures and the two transition times. The transition period is less than 10 seconds at 25 °C. The test duration is 100 cycles. Samples of surface mount devices must undergo preconditioning and pass a final electrical test prior to the thermal shock test.

Autoclave or Pressure Cooker Test
Procedure: JESD22-A102-C / EIAJ-IC-121-18

Purpose: The pressure cooker test is an environmental test that measures device resistance to moisture penetration and the effect of galvanic corrosion. Samples of surface mount devices are subjected to preconditioning and a final electrical test prior to the pressure cooker test. After the pressure cooker test, the leads of the test samples are cleaned and then baked at 150 °C for 1 hour before the final electrical test.

Temperature Cycling (TC) Air to Air
Procedure: JESD22-A104-B /Mil-Std-883 Method 1010.7

Purpose: Temperature cycle testing is to study the effect of thermal expansion mismatch among the different components within a specific die and packaging system. The cycling test system has a cold dwell at - 65 or –55°C and a hot dwell at 150 or 125 °C. It employs a circulating air environment to ensure rapid stabilization at a specified temperature. During temperature cycle testing, devices are inserted into the cycling test system and held at cold dwell for 15 minutes, and then the devices are heated to hot dwell for 15 minutes. One cycle includes the duration at both extreme temperatures and the two transition times. The transition period is less than one minute at 25°C. Samples of surface mount devices must first undergo preconditioning and pass a final electrical test prior to the temperature cycle test.

Temperature Humidity Bias Lifetest 85oC/85%
Procedure: JESD22-A101-B

Purpose: The purpose is to evaluate the reliability of non-hermetic solid state devices
in a humid environment.

Temperature-Humidity-Bias Test (THB)
Procedure: (EIAJ-IC-121-17)

Purpose: The temperature-humidity-bias test is an environmental test designed to measure the corrosion and moisture resistance of plastic-encapsulated circuits. A nominal reverse bias is applied to the device to create electrolytic cells necessary to accelerate corrosion of the metallization or bond pads without heating the device. The duration of the test is 1000 hours, with readouts (final electrical tests) at 168 hours and 500 hours during the test. The stress temperature is 85 °C, and the humidity is RH 85%. The bias is the maximum operating voltage. Samples of surface mount devices must undergo preconditioning and pass a final electrical test prior the THB test

HTOL (High Temperature Operating Lifetest)
Procedure: JESD22-A108-B

Purpose: High temperature operating life (HTOL) test is to determine the reliability of products by accelerating thermally activated failure mechanisms by subjecting samples to extreme temperatures under biased operating conditions. The test is used to predict long term failure rates. All test samples are screened directly after final electrical testing. The oven temperature for the HTOL test is 125 °C. Testing is performed with dynamic signals applied to the device. The typical Vcc is the maximum operating voltage.

High-Temperature Storage Life Test (HTSL)
Procedure: MIL-STD-883 Method 1008 / JESD22-A103-B

Purpose: The high-temperature storage life test measures device resistance to a high-temperature environment that simulates a storage environment. The stress temperature is set to 150°C or 125°C to accelerate the effect of temperature on the test samples. In the test, no voltage bias is applied to the devices.

Bias Life Test (BLT)
Procedure: MIL-STD-883 Method 1005.8 / EIAJ-ED4701-D323

Purpose: Bias life test is to detect possible defects on passivation (contamination, surface inversion, un-stable characteristics of film), PN junction (junction degradation), oxide film (mobile ions, interface states), and bonding (open moralization, bonding defect). The test temperature is 125 °C and the duration is 1000 hours. The pins of the devices are combination biased.

Preconditioning
Procedure: JESD22-A113-B

Purpose: Preconditioning is to measure the resistance of surface mount devices to the storage environment at the customer site and to thermal stress created by IR reflow. Before they undergo the temperature humidity bias test, the temperature cycle test, the thermal shock test, the pressure cooker test or the highly-accelerated temperature and humidity stress test, surface mount devices are subjected to preconditioning and must then pass a final electrical test

Real Time Thermal Profiling
Procedure: IPC/JEDEC J-STD-020B / JESD22-A113-B

Purpose: To insure that the reflow profile requirements for each specific package is met during the reflow process for preconditioning. Thermal profiling also verifies the specified ramp/soak times and temperature are met for temperature cycle and thermal shock.

Solderability
Procedure: JESP22-B102 / Mil-Std-883 Method 2003.7

Purpose: To evaluate the solderability of terminations that are normally joined by a soldering operation. The evaluation is made on the basis of the ability of the terminations to be wetted by a coating of solder, and to produce a suitable fillet when dipped in solder. An accelerated aging test is required that simulates natural aging under a combination of various storage conditions that have different deleterious effects.

Fine and Gross Leak Testing (Seal)
Procedure: Mil- Std-883E Method 1014.9